| << Topic |
< Post |
Post 4 of 7 Topic 6104 of 6187
|
Post > |
Topic >> |
Re: Need replacements for CL905HL , CL905HN , CDS cell
by legg <legg@[EMAIL PROTECTED]
>
Oct 7, 2008 at 03:10 PM
| On 6 Oct 2008 21:19:17 GMT, ba221@[EMAIL PROTECTED]
(Gaetan
Mailloux) wrote:
>John Fields (jfields@[EMAIL PROTECTED]
) writes:
>> On 6 Oct 2008 08:25:14 GMT, ba221@[EMAIL PROTECTED]
(Gaetan Mailloux)
>> wrote:
>>
>>>Hello
>>>
>>>Anyone know any modern replacements numbers for CL905HL and CL905HN ,
they are
>>>CDS photoresistors.
>>>
>>>I did try with Google but found nothing.
>>
>> ---
>> Go to:
>>
>> http://www.clairex.com/
>>
>> and click on
>> JF
>
>
>Hello
>
>Clairex do not have any replacements for them.
>
>Here is the specs of those CDS cells;
>
>
>CL905HL , CDS cell
>
>
>Spectral Peak (nm): 550
>
>Resistance at 2 ftc (Ohms): 100K
>
>Min Dark Resistance (Ohms): 67 meg
>
>Maximum Voltage (Peak AC or DC): 100 volt
>
>---
>
>CL905HN , CDS cell
>
>
>Spectral Peak (nm): 550
>
>Resistance at 2 ftc (Ohms): 700K
>
>Min Dark Resistance (Ohms): 467 meg
>
>Maximum Voltage (Peak AC or DC): 100 volt
>
There is likely no issue with electrically equivalent parts, as all
CDS have high stand-off voltages and most have equal or lower
illuminated impedances.
Search CDS or PDV-P at digikey.
RL


|
7 Posts in Topic:
|
ba221@[EMAIL PROTECTED]
|
2008-10-06 08:25:14 |
|
John Fields <jfields@[ |
2008-10-06 10:00:31 |
|
ba221@[EMAIL PROTECTED]
|
2008-10-06 21:19:17 |
|
legg <legg@[EMAIL PROT |
2008-10-07 15:10:27 |
|
Franc Zabkar <fzabkar@ |
2008-10-14 06:29:00 |
|
"Michael A. Terrell& |
2008-10-06 11:02:45 |
|
John Fields <jfields@[ |
2008-10-06 10:05:56 |
|
Post A Reply:

|
|
|
|