Talk About Network

Google


Register and Login
Nick
Password
Register create new account Sign up is FREE and you can post replies, new topics, bookmark posts and more!
Recover lost password


Electronic Equipment > Electronics Design > Ground pour rem...
Latest [ Topics | Posts ] Archive Post A New Topic Post a Reply
<< Topic < Post Post 1 of 4 Topic 32143 of 33980
Post > Topic >>

Ground pour removal around Ethernet & USB traces

by "Joel Koltner" <zapwireDASHgroups@[EMAIL PROTECTED] > Jun 30, 2008 at 10:57 AM

Anyone know why Asus removed their (not really needed, IMO, and sometimes
much 
more of a hassle than it's worth) ground pour around their Ethernet and
USB 
connectors as shown here --> 
http://wiki.openwrt.org/OpenWrtDocs/Hardware/Asus/WL500GP/IMG_0007
?  Is
it 
possibly a UL/CE "safety" thing in that, at least for Ethernet, there
could be 
a largish common mode voltage kicking around?
 




 4 Posts in Topic:
Ground pour removal around Ethernet & USB traces
"Joel Koltner"   2008-06-30 10:57:51 
Re: Ground pour removal around Ethernet & USB traces
DJ Delorie <dj@[EMAIL   2008-06-30 14:13:11 
Re: Ground pour removal around Ethernet & USB traces
"Arie" <no.s  2008-06-30 22:54:43 
Re: Ground pour removal around Ethernet & USB traces
"Joel Koltner"   2008-06-30 14:07:57 