by default <edmoneyfromlanailstudio@[EMAIL PROTECTED] > Apr 18, 2008 at 01:09 AM

I am writting at my diploma thesis with an EMC theme.

If got a power fan (13V / 6A) witch produces conducted emissions, so I
have to reduce them to achieve CISPR25.
Up to 40MHz I found an easy solving with LC lowpass filter, but over
50MHz I am out of the CISPR25 limit.

Does anybody have experiences in EMC design in high frequency bands,
doesn't have?

I think about solving it like the motherboard producers do, they
design there signals like little inductors and so one.
But I didn't find any guidlines to do this like them.
 




 6 Posts in Topic:
reducing Conducted Emission from Power Fan in high frequency ban
default <edmoneyfromla  2008-04-18 01:09:32 
Re: reducing Conducted Emission from Power Fan in high frequency
"hrhofmann@[EMAIL PR  2008-04-18 19:32:59 
Re: reducing Conducted Emission from Power Fan in high frequency
default <edmoneyfromla  2008-04-19 09:07:47 
Re: reducing Conducted Emission from Power Fan in high frequency
"hrhofmann@[EMAIL PR  2008-04-19 13:31:28 
Re: reducing Conducted Emission from Power Fan in high frequency
default <edmoneyfromla  2008-04-20 05:39:55 
Re: reducing Conducted Emission from Power Fan in high frequency
"hrhofmann@[EMAIL PR  2008-04-20 08:28:01 